Showing results: 31 - 33 of 33 items found.
-
MODEL LCA-RTC -
Transducer Techniques, Inc
The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
Model UDA -
tecsis LP
Model UDA is a universal signal conditioner and amplifier designed for use with all full bridge, strain gage-based transducers. Model UDA turns the analog signal into a user-selectable output of ±5Vdc, ±10Vdc, or 4-20mA. This versatile unit features selectable excitation of 2.5 or 5.0Vdc bridge voltage and has a wide DC power input range from 11 to 28Vdc to adapt to a variety of installations. Model UDA includes a wide zero and span adjustment range and a symmetry adjustment for applications requiring precision in both tension and compression. The configurable low pass filter actively removes unwanted high frequency signal components. The unit is housed in a rugged DIN-mountable enclosure with screw terminals to provide connection for power, analog output, shunt calibration, and sensor signals.
-
66205 -
Chroma Systems Solutions, Inc.
Voltage Ranges:15/30/60/150/300/600 Vrms1200Vrms (optional)Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bitsAnalog/Digital converters withmax samipling rate up to 250kHzCapable of meeting the IEC 61000-4-7harmonics measurement requirementsSmart Range function provides seamlesspower integration measurement underauto range modeSupports external shunt and CT forhigher current applications5 mA minimum current range &0.1mW power resolutionMeets ENERGY STAR /EN 50564/IEC 62301/ErP requirementsUser-define criteria providesautomatic PASS/FAIL indicationsTHD and user-specify order distortionmeasurementInrush current and energy measurementsVoltage/ Current harmonics measurementsup to 100 ordersUSB (Host) interface provides data loggingfunctionalitySupport GPIB, USB, RS232, LAN (option)interface